NXL Wedge Tension Clamps
NXL wedge clamps secure aluminium overhead conductors at angle or dead-end poles on distribution lines rated up to 10 kV.
- Series
- NXL
- Voltage class
- Up to 10 kV
- Model entries
- 10
Used inOverhead Distribution Lines
Choose a model
Model
NXL-1
- Overhead insulated aluminium conductor (mm²)
- 35
- Stripping length (mm)
- 245
- Grip strength (kN)
- 3.4
- Nominal failure load (kN)
- 7.5
- Matching insulation cover
- NXL-1(25-50)
Model
NXL-1
- Overhead insulated aluminium conductor (mm²)
- 50
- Stripping length (mm)
- 245
- Grip strength (kN)
- 4.6
- Nominal failure load (kN)
- 7.5
- Matching insulation cover
- NXL-1(25-50)
Model
NXL-2
- Overhead insulated aluminium conductor (mm²)
- 70
- Stripping length (mm)
- 245
- Grip strength (kN)
- 6.7
- Nominal failure load (kN)
- 14.5
- Matching insulation cover
- NXL-2(70-95)
Model
NXL-2
- Overhead insulated aluminium conductor (mm²)
- 95
- Stripping length (mm)
- 245
- Grip strength (kN)
- 8.9
- Nominal failure load (kN)
- 14.5
- Matching insulation cover
- NXL-2(70-95)
Model
NXL-3
- Overhead insulated aluminium conductor (mm²)
- 120
- Stripping length (mm)
- 255
- Grip strength (kN)
- 11.3
- Nominal failure load (kN)
- 23.4
- Matching insulation cover
- NXL-3(120-150)
Model
NXL-3
- Overhead insulated aluminium conductor (mm²)
- 150
- Stripping length (mm)
- 255
- Grip strength (kN)
- 13.7
- Nominal failure load (kN)
- 23.4
- Matching insulation cover
- NXL-3(120-150)
Model
NXL-4
- Overhead insulated aluminium conductor (mm²)
- 185
- Stripping length (mm)
- 300
- Grip strength (kN)
- 17.3
- Nominal failure load (kN)
- 36.4
- Matching insulation cover
- NXL-4(185-240)
Model
NXL-4
- Overhead insulated aluminium conductor (mm²)
- 240
- Stripping length (mm)
- 300
- Grip strength (kN)
- 22.5
- Nominal failure load (kN)
- 36.4
- Matching insulation cover
- NXL-4(185-240)
Model
NXL-5
- Overhead insulated aluminium conductor (mm²)
- 300
- Stripping length (mm)
- 320
- Grip strength (kN)
- 28.2
- Nominal failure load (kN)
- 61
- Matching insulation cover
- NXL-5(300-400)
Model
NXL-5
- Overhead insulated aluminium conductor (mm²)
- 400
- Stripping length (mm)
- 320
- Grip strength (kN)
- 39.8
- Nominal failure load (kN)
- 61
- Matching insulation cover
- NXL-5(300-400)
Compare all 10 models in a table
| Save model | Model | Overhead insulated aluminium conductor (mm²) | Stripping length (mm) | Grip strength (kN) | Nominal failure load (kN) | Matching insulation cover |
|---|---|---|---|---|---|---|
| 35 | 245 | 3.4 | 7.5 | NXL-1(25-50) | ||
| 50 | 245 | 4.6 | 7.5 | NXL-1(25-50) | ||
| 70 | 245 | 6.7 | 14.5 | NXL-2(70-95) | ||
| 95 | 245 | 8.9 | 14.5 | NXL-2(70-95) | ||
| 120 | 255 | 11.3 | 23.4 | NXL-3(120-150) | ||
| 150 | 255 | 13.7 | 23.4 | NXL-3(120-150) | ||
| 185 | 300 | 17.3 | 36.4 | NXL-4(185-240) | ||
| 240 | 300 | 22.5 | 36.4 | NXL-4(185-240) | ||
| 300 | 320 | 28.2 | 61 | NXL-5(300-400) | ||
| 400 | 320 | 39.8 | 61 | NXL-5(300-400) |
How to select
- Choose the table row for the conductor size and confirm the stripping length, grip strength and matching insulation cover.