Insulation Piercing & Earthing Clamps
1 kV Insulation Piercing Connectors
Insulation piercing connectors make a tap connection on insulated low-voltage line without stripping the insulation.
- Series
- JJC
- Voltage class
- 1 kV
- Model entries
- 9
Used inOverhead Distribution Lines
Choose a model
Model
JJC2-95
- Rated voltage (kV)
- 1
- Main line cross-section (mm²)
- 16~95
- Branch line cross-section (mm²)
- 4~35(50)
- Nominal current (A)
- 138
- Overall size (mm)
- 46×52×87
- Bolts (qty)
- 1
Model
JJC1-95
- Rated voltage (kV)
- 1
- Main line cross-section (mm²)
- 16~95
- Branch line cross-section (mm²)
- 1.5~10
- Nominal current (A)
- 75
- Overall size (mm)
- 27×41×62
- Bolts (qty)
- 1
Model
JJC1-35
- Rated voltage (kV)
- 1
- Main line cross-section (mm²)
- 1.5~35
- Branch line cross-section (mm²)
- 1.5~10
- Nominal current (A)
- 75
- Overall size (mm)
- 27×41×62
- Bolts (qty)
- 1
Model
JJC2-150
- Rated voltage (kV)
- 1
- Main line cross-section (mm²)
- 50~150
- Branch line cross-section (mm²)
- 6~30(50)
- Nominal current (A)
- 157
- Overall size (mm)
- 46×52×87
- Bolts (qty)
- 1
Model
JJC3-120
- Rated voltage (kV)
- 1
- Main line cross-section (mm²)
- 16~120
- Branch line cross-section (mm²)
- 16~120
- Nominal current (A)
- 342
- Overall size (mm)
- 50×61×100
- Bolts (qty)
- 1
Model
JJC3-95
- Rated voltage (kV)
- 1
- Main line cross-section (mm²)
- 25~95
- Branch line cross-section (mm²)
- 25~95
- Nominal current (A)
- 214
- Overall size (mm)
- 50x61x100
- Bolts (qty)
- 1
Model
JJC5-240
- Rated voltage (kV)
- 1
- Main line cross-section (mm²)
- 120~240
- Branch line cross-section (mm²)
- 6~35(50)
- Nominal current (A)
- 425
- Overall size (mm)
- 60×80×105
- Bolts (qty)
- 1
Model
JJC3-150
- Rated voltage (kV)
- 1
- Main line cross-section (mm²)
- 35~150
- Branch line cross-section (mm²)
- 35~150
- Nominal current (A)
- 342
- Overall size (mm)
- 50x61x100
- Bolts (qty)
- 1
Model
JJC4-240
- Rated voltage (kV)
- 1
- Main line cross-section (mm²)
- 120~240
- Branch line cross-section (mm²)
- 25~120(150)
- Nominal current (A)
- 211
- Overall size (mm)
- 52x68x100
- Bolts (qty)
- 1
Compare all 9 models in a table
| Save model | Model | Rated voltage (kV) | Main line cross-section (mm²) | Branch line cross-section (mm²) | Nominal current (A) | Overall size (mm) | Bolts (qty) |
|---|---|---|---|---|---|---|---|
| 1 | 16~95 | 4~35(50) | 138 | 46×52×87 | 1 | ||
| 1 | 16~95 | 1.5~10 | 75 | 27×41×62 | 1 | ||
| 1 | 1.5~35 | 1.5~10 | 75 | 27×41×62 | 1 | ||
| 1 | 50~150 | 6~30(50) | 157 | 46×52×87 | 1 | ||
| 1 | 16~120 | 16~120 | 342 | 50×61×100 | 1 | ||
| 1 | 25~95 | 25~95 | 214 | 50x61x100 | 1 | ||
| 1 | 120~240 | 6~35(50) | 425 | 60×80×105 | 1 | ||
| 1 | 35~150 | 35~150 | 342 | 50x61x100 | 1 | ||
| 1 | 120~240 | 25~120(150) | 211 | 52x68x100 | 1 |
How to select
- Match both the main line and the branch line cross-section ranges. Check nominal current for the branch load.
Questions
Do I need to strip the cable?
No. The contact teeth pierce the insulation of both conductors as the bolt is tightened.